New 2021 Realistic NS0-194 Dumps Test Engine Exam Questions in here
Updated Official licence for NS0-194 Certified by NS0-194 Dumps PDF
NetApp NS0-194 Exam Topics:
| Section | Objectives |
|---|---|
| Troubleshooting NetApp Hardware and Software | -Demonstrate knowledge of how to collect and analyze information -Demonstrate knowledge of how to troubleshoot data access problems -Demonstrate knowledge of how to analyze performance |
| NetApp Hardware | -Identify the FRUs in a NetApp system -Demonstrate knowledge of the hardware replacement process -Describe storage hardware technology -Describe compute technology |
| ONTAP OS | -Describe disk or aggregate concepts -Describe volume concepts -Describe ONTAP networking concepts -Describe how ONTAP interacts with external components -Identify ONTAP logging mechanisms -Describe supported ONTAP protocols |
| NetApp Cloud Data Services | -Identify the components of cloud data services -Identify the components of a hybrid cloud solution |
| Active IQ | -Describe how to use Active IQ |
| Data Protection | -Identify data protection concepts -Demonstrate knowledge of data protection operations |
NEW QUESTION 65
A customer is showing disk utilization is at 100% in Active IQ even though there are low protocol operations on the controller. You review the data shown in the exhibit.
In this situation, what should you do?
- A. Replace disks 6b.34 and 6a.19.
- B. Replace disk 6b.39.
- C. Add disks to the aggregate to bring down the average utilization.
- D. Reseat shelf module B.
Answer: B
NEW QUESTION 66
While troubleshooting intermittent takeover impossible command entries on the console, you request the output of the storage failover interconnect statistics error show command.
Which two counters would help troubleshoot this problem? (Choose two.)
- A. peer connections lost
- B. sent queue length counter
- C. link error recovery counter
- D. avg peer connection time
Answer: B,C
NEW QUESTION 67
Snap Drive for Windows has been installed and configured on a VMware virtual machine. The virtual machine has been configured with raw device mappings (RDMs) that are mapped to LUNs on a NetApp storage controller.
The RDMs can be seen as connected disks in Windows Disk Management.
However, Snap Drive is not enumerating the RDMs.
Which action will solve the problem in this scenario?
- A. Snap Drive must be installed on tin* VhtualCenter server.
- B. Virtual Center or ESX servor logon settings must bo enabled and configured.
- C. Snap Drive must have the preferred storage IP addresses configured.
- D. Snap Drive and Virtual Storage Console (VSC) integration must be configured.
Answer: D
NEW QUESTION 68
Which three conditions would prevent a normal giveback operation? (Choose three.)
- A. ongoing SnapMirror updates
- B. established CIFS sessions
- C. LUNs mapped with ALUA enabled
- D. presence of failed disks
- E. established NFSv3 sessions
Answer: A,B,D
NEW QUESTION 69
You are migrating volumes from an older aggregate to a new aggregate using the vol move command. You notice that, after completion, access to these volumes is slower until a certain process finishes.
Which process is causing the problem in this scenario?
- A. container block reclamation
- B. active bitmap rearrangement
- C. deswizzling
- D. snap create
Answer: D
NEW QUESTION 70
You receive an AutoSupport notification because of the error shown below. "HA GROUP ERROR: DISK/SHELF COUNT MISMATCH ERROR."
In this scenario, which two steps would you take to solve the problem? (Choose two.)
- A. You should power cycle all the disk shelves to clear the error.
- B. You should perform a failover and a giveback to clear the error.
- C. You should review the /etc/messages log.
- D. You should examine the IOM modules for error lights and reseat.
Answer: A,C
NEW QUESTION 71
Which two transport protocols would be used for SnapDrive for Windows in both 7-Mode and clustered Data ONTAP environments? (Choose two.)
- A. HTTPS
- B. HTTP
- C. iSCSI
- D. RPC
Answer: A,C
NEW QUESTION 72
Your customer's MetroCluster has generated a "DISK REDUNDANCY FAILED" message.
Netapp-EmA:
Tue Jan 14 04:12:12 CET [netapp-EmA:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv' failed.
Tue Jan 14 04:12:13 CET [netapp-EmA:rv.connection.torndown:info]: HA interconnect: cfo_rv1 is torn down on NIC 1.
Tue Jan 14 04:12:13 CET [netapp-EmA:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'1 failed.
Tue Jan 14 04:12:15 CET [netapp-EmA:rv.connection.torndown:info]: HA interconnect: cfo_rv2 is torn down on NIC 1.
Tue Jan 14 04:12:18 CET [netapp-EmA:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'2 failed.
Tue Jan 14 04:12:19 CET [netapp-EmA:bridge.removed:info]: FC-to_SAS bridge siteB_2:13.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111161] was removed Tue Jan 14 04:12:19 CET [netapp-EmA:bridge.removed:info]: FC-to_SAS bridge siteB_2:5.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111160] was removed Netapp-EmB:
Tue Jan 14 04:12:12 CET [netapp-EmB:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv' failed.
Tue Jan 14 04:12:12 CET [netapp-EmB:rv.connection.torndown:info]: HA interconnect: cfo_rv2 is torn down on NIC 1.
Tue Jan 14 04:12:13 CET [netapp-EmB:rv.connection.torndown:info]: HA interconnect: cfo_rv1 is torn down on NIC 1.
Tue Jan 14 04:12:13 CET [netapp-EmB:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'1 failed.
Tue Jan 14 04:12:18 CET [netapp-EmB:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'2 failed.
Tue Jan 14 04:12:19 CET [netapp-EmB:bridge.removed:info]: FC-to_SAS bridge siteA_2:13.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111167] was removed Tue Jan 14 04:12:19 CET [netapp-EmB:bridge.removed:info]: FC-to_SAS bridge siteA_2:5.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111164] was removed Referring to the messages shown in the exhibit for each node, which component is causing the problem?
- A. the ISL between siteA and site B
- B. the SAN switch siteA_2
- C. the SAN switch siteB_2
- D. the ATTO bridge on siteB_2
Answer: A
NEW QUESTION 73
While troubleshooting client access issues to a CIFS share, you notice that the issue only occurs when the data LIF that the clients are accessing is on a specific node in the cluster.
In this scenario, which configuration should you review to determine why this issue is happening?
- A. cluster health
- B. share path
- C. export policies
- D. Kerberos
Answer: D
NEW QUESTION 74
What is the consequence of a loss of connectivity between a Cloud Volumes ONTAP (CVO) instance and Cloud Manager for four or more days?
- A. The CVO instance sends an AutoSupport message.
- B. Cloud Manager removes the CVO instance from its inventory.
- C. The CVO instance is stopped.
- D. The CVO instance must be added back manually to Cloud Manager.
Answer: B
NEW QUESTION 75
Test user "LAB\tester" can perform an operation in the CIFS share "HR" from the SVM "svm1". However, the rest of the users from the HR department cannot perform the same operation. You want to determine why only
"LAB\tester" can perform the operation.
In this scenario, which security trace filter accomplishes this task?
- A. vserver security trace filter create -vserver svm1 -index 1 -protocol nfs - unix-name tester -trace-allow no
- B. vserver security trace filter create -vserver svm1 -index 1 -protocol nfs - unix-name tester -trace-allow yes
- C. vserver security trace filter create -vserver svm1 -index 1 -protocol cifs - windows- name LAB\tester
-trace-allow yes - D. vserver security trace filter create -vserver svm1 -index 1 -protocol cifs - windows- name LAB\tester
-trace-allow no
Answer: C
NEW QUESTION 76
A customer discovers fault lights on both HA interconnect links in a 2-node cluster. The customer is concerned about the cluster's ability to serve data.
Which statement is true in this scenario?
- A. ONTAP clustering does not depend on HA interconnect links and will continue to serve data.
- B. You should reboot both nodes.
- C. The HA interconnect links would automatically recover from this temporary state.
- D. You should perform a takeover and serve the data in failover state.
Answer: A
NEW QUESTION 77
A client is attempting to mount a UNIX security style volume using NFSv4. The client receives the
"permission denied" message, but mounting NFSv3 works fine. You have confirmed both NFSv4 and NFSv3 are allowed in the export policy.
Which statement describes this behavior?
- A. The export policy applied to the volume has superuser set to none.
- B. There is no proper name-mapping rule for the user mounting.
- C. NFSv4 takes file permissions into account when mounting.
- D. Extended groups for AUTH_SYS are enabled.
Answer: D
NEW QUESTION 78
You have an ONTAP 9.3 cluster and create a new SnapMirror relationship with a SnapMirror type of DP. You initialization the SnapMirror relationship and verify that incremental updates are operating as expected.
However, you notice that the SnapMirror type is XDP instead of the specified DP.
In this scenario, which statement is correct?
- A. DP is not supported in ONTAP 9.3.
- B. All new relationships default to XDP.
- C. The destination cluster is running an older version of ONTAP.
- D. The SnapMirror policy type was set to MirrorAllSnapshots.
Answer: B
NEW QUESTION 79
Which two vetoes can be over-ridden during an aggregate relocation or giveback? (Choose two.)
- A. RAID
- B. Lock Manager
- C. Vol Move
- D. Disk Inventory
Answer: A,C
NEW QUESTION 80
Which three transport protocols are used to deliver AutoSupport data to NetApp? (Choose three.)
- A. SSH
- B. HTTPS
- C. FTP
- D. SMTP
- E. HTTP
Answer: B,C,E
NEW QUESTION 81
Which three techniques are used in ONTAP to improve storage efficiencies? (Choose three.)
- A. compression
- B. thin provisioning
- C. ADP
- D. compaction
- E. encryption
Answer: A,B,D
NEW QUESTION 82
Which two conditions would prevent a normal giveback operation? (Choose two.)
- A. Active SnapMirror transfer
- B. The presence of failed disks
- C. The presence of a failed IOM module
- D. Connected NFsv3 sessions
Answer: B,C
NEW QUESTION 83
Which NetApp HCI component communicates with activeiq.solidfire.com and the Cloud Data Services portal?
- A. the NetApp Element software vSphere plug-in
- B. the NetApp Trident software
- C. the management node (mNode)
- D. the NetApp Element software Management Interface
Answer: C
NEW QUESTION 84
Your customer's MetroCluster has generated a "DISK REDUNDANCY FAILED" message.
Netapp-EmA:
Tue Jan 14 04:12:12 CET [netapp-EmA:cf.rv.notConnected:error]: HA
interconnect: Connection for 'cfo_rv' failed.
Tue Jan 14 04:12:13 CET [netapp-EmA:rv.connection.torndown:info]: HA
interconnect: cfo_rv1 is torn down on NIC 1.
Tue Jan 14 04:12:13 CET [netapp-EmA:cf.rv.notConnected:error]: HA
interconnect: Connection for 'cfo_rv'1 failed.
Tue Jan 14 04:12:15 CET [netapp-EmA:rv.connection.torndown:info]: HA
interconnect: cfo_rv2 is torn down on NIC 1.
Tue Jan 14 04:12:18 CET [netapp-EmA:cf.rv.notConnected:error]: HA
interconnect: Connection for 'cfo_rv'2 failed.
Tue Jan 14 04:12:19 CET [netapp-EmA:bridge.removed:info]: FC-to_SAS bridge siteB_2:13.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111161] was removed Tue Jan 14 04:12:19 CET [netapp-EmA:bridge.removed:info]: FC-to_SAS bridge siteB_2:5.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111160] was removed Netapp-EmB:
Tue Jan 14 04:12:12 CET [netapp-EmB:cf.rv.notConnected:error]: HA
interconnect: Connection for 'cfo_rv' failed.
Tue Jan 14 04:12:12 CET [netapp-EmB:rv.connection.torndown:info]: HA
interconnect: cfo_rv2 is torn down on NIC 1.
Tue Jan 14 04:12:13 CET [netapp-EmB:rv.connection.torndown:info]: HA
interconnect: cfo_rv1 is torn down on NIC 1.
Tue Jan 14 04:12:13 CET [netapp-EmB:cf.rv.notConnected:error]: HA
interconnect: Connection for 'cfo_rv'1 failed.
Tue Jan 14 04:12:18 CET [netapp-EmB:cf.rv.notConnected:error]: HA
interconnect: Connection for 'cfo_rv'2 failed.
Tue Jan 14 04:12:19 CET [netapp-EmB:bridge.removed:info]: FC-to_SAS bridge siteA_2:13.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111167] was removed Tue Jan 14 04:12:19 CET [netapp-EmB:bridge.removed:info]: FC-to_SAS bridge siteA_2:5.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111164] was removed Referring to the messages shown in the exhibit for each node, which component is causing the problem?
- A. the ISL between siteA and site B
- B. the SAN switch siteA_2
- C. the SAN switch siteB_2
- D. the ATTO bridge on siteB_2
Answer: A
NEW QUESTION 85
......
NetApp NS0-194 Exam Certification Details:
| Exam Registration | PEARSON VUE |
| Recommended Training | Introduction to NetApp Storage System Basic Components (WBT) Introduction to Clustered Data ONTAP Architecture (WBT) Introduction to Aggregates and FlexVols in Clustered Data ONTAP (WBT) Introduction to Networking in Clustered Data ONTAP (WBT) Introduction to High-Availability in Clustered Data ONTAP (WBT) Introduction to Data Protection in Clustered Data ONTAP (WBT) |
| Exam Name | Support Engineer |
| Passing Score | 63% |
| Exam Price | $150 USD |
| Duration | 90 minutes |
| Sample Questions | NetApp NS0-194 Sample Questions |
| Exam Code | NS0-194 NCSE |
| Number of Questions | 60 |
Grab latest Network Appliance NS0-194 Dumps as PDF Updated: https://www.lead1pass.com/NetworkAppliance/NS0-194-practice-exam-dumps.html
Newly Released NS0-194 Dumps for Network Appliance NCSE Certified: https://drive.google.com/open?id=1Jq6VELmp6chDfcD2_aaFLKRksuLgYZ3S