BICSI DCDC-002 exam is a computer-based test that consists of 100 multiple-choice questions. DCDC-002 exam duration is four hours, and candidates must score 70% or higher to pass the exam. DCDC-002 exam is conducted at Pearson VUE testing centers worldwide, and candidates can register for the exam on the BICSI website.

 

NEW QUESTION # 45
What is the recommended range of temperature for a data center?

  • A. 18-22°C (64-72°F)
  • B. 24-28°C (75-82°F)
  • C. 26-30°C (79-86°F)
  • D. 20-24°C (68-75°F)
  • E. 22-26°C (72-79°F)

Answer: D


NEW QUESTION # 46
What is the recommendation regarding row length?

  • A. Ten Racks in Length
  • B. All
  • C. Do not exceed 20 racks in length and dead-end rows not to exceed ten racks long
  • D. Maximum twenty-five racks in each row only
  • E. None

Answer: C


NEW QUESTION # 47
What is the clearance required between cabinets and the perimeter wall?

  • A. 8 ft
  • B. 4 ft
  • C. 2 ft
  • D. 6 ft

Answer: B


NEW QUESTION # 48
Why do larger data centers require more H DAs?

  • A. to ensure maximum horizontal cable lengths are not exceeded and to avoid cable congestion
  • B. to reduce energy consumption and carbon footprint
  • C. to increase server processing speed by minimizing latency
  • D. to provide redundancy and failover mechanisms

Answer: A


NEW QUESTION # 49
What is a possible downside to customer-owned maintenance holes?

  • A. leaks leading to water infiltration into data center
  • B. fire risk near data center property
  • C. susceptibility to theft or damage by unauthorized personnel
  • D. poor aesthetic appearance around facility exterior

Answer: A


NEW QUESTION # 50
What is the recommended range for the low temperature in a data center according to ASHRAE?

  • A. 70 degrees
  • B. 75 degrees
  • C. 64.4 degrees
  • D. 55 degrees
  • E. 60 degrees

Answer: C


NEW QUESTION # 51
How do you calculate thermal load in a data center?

  • A. IT Thermal Output + Lighting System
  • B. IT Thermal Output + Cooling System + Lighting System
  • C. IT Thermal Output + Cooling System + Lighting System + PDU System
  • D. IT Thermal Output + Cooling System
  • E. IT Thermal Output + PDU System

Answer: C


NEW QUESTION # 52
what are the two rooms that may require 2 exits?

  • A. Water Supply Rooms
  • B. the electrical Room and battery room
  • C. Equipment Room and Security Rooms
  • D. Mechanical Room and Electrical
  • E. Computing rooms And Storage rooms

Answer: B

Explanation:
Explanation


NEW QUESTION # 53
How many air changes an hour inside an equipment room?

  • A. 0.25
  • B. 2.00
  • C. 1.50
  • D. 1.00
  • E. 0.50

Answer: A


NEW QUESTION # 54
What is the formula for reliability of components in parallel?

  • A. R = 1 - ([1-RA1) * (1-RA2)]
  • B. R = RA1 / RA2
  • C. R = RA1 - RA2
  • D. R = RA1 + RA2

Answer: A


NEW QUESTION # 55
What is the minimum aisle width?

  • A. Arm span distance between technicians
  • B. 3 feet
  • C. Twice server cabinet depth
  • D. The width shouldn't exceed more than half room length

Answer: B


NEW QUESTION # 56
What IBC occupancy category are data centers placed in if they don't have to operate after an earthquake?

  • A. Category 4
  • B. Category3
  • C. Category1
  • D. Category2

Answer: D


NEW QUESTION # 57
What are the speed and distance limitations of ESCON?

  • A. 17 MB/s @ up to 60km
  • B. 100 Mbps @ up to 20km
  • C. 1 Gbps @ up to 100m
  • D. 10 Gbps @ up to 40km

Answer: A


NEW QUESTION # 58
What is the minimum thickness of an elevated floor topping over metal flutes?

  • A. 2 inchmhes
    B, 3 Inches
  • B. 4 Inches
  • C. 1,5Inchessa.i:sab#v=onepage&q&f=.htm&ebrary=&qp=end+user+bicsi+f2590b67561c7dcea431ec3e26ae

Answer: C


NEW QUESTION # 59
According to NEB, what is the recommended range for the low temperature in a data center?

  • A. 65 degrees
  • B. 70 degrees
  • C. 75 degrees
  • D. 55 degrees
  • E. 60 degrees

Answer: A


NEW QUESTION # 60
What is the minimum distance from the bottom of the access floor to the top of the cable tray?

  • A. 3 inches
  • B. 4 inches
  • C. 2 inches
  • D. 1 inch
  • E. 5 inches

Answer: C


NEW QUESTION # 61
What is the preferred location of the power distribution unit?

  • A. under each server rack
  • B. in an unused area of another floor
  • C. inside a ventilation duct
  • D. a service gallery outside the computer room, if the A H J and feeder distances allow

Answer: D


NEW QUESTION # 62
What is the recommended fire suppression system for a data center?

  • A. None of the above
  • B. Foam-based
  • C. Gas-based
  • D. Water-based
  • E. Powder-based

Answer: C


NEW QUESTION # 63
How often is there typically a technology refresh in a data center?

  • A. There is no typical refresh cycle
  • B. Every 3-5 years
  • C. Every 1-2 years
  • D. Every 7-10 years

Answer: B


NEW QUESTION # 64
What is the recommended headroom for overhead cable tray?

  • A. 9"
  • B. 3"
  • C. 12"
  • D. 6"

Answer: C


NEW QUESTION # 65
What is the Fourth Preference Regarding Utility Service?

  • A. One circuit from one substation, separate paths
  • B. At least two circuits from one substation fed via alternative power grid
  • C. Two balanced feeds with different voltages derived from a single distribution station
  • D. At least four circuits each from different distribution stations but fed via common feeders

Answer: A


NEW QUESTION # 66
......